BUILDING FACT SHEET
|
1. Floor-To-Floor Height:
|
|
Slab/Slab
|
|
|
Ground to 2nd | *25-0"
|
|
Ground to Mezzanine |
*8'-0" |
|
|
2nd and 3rd | 14'-1"
|
|
|
4th |
14'-6" |
|
|
5th |
12'-1" |
|
|
6th |
13'-0" |
|
|
7th |
13'-4" |
|
|
8th |
13'-1" |
|
|
9th |
13'-1" |
|
|
10th |
13'-1" |
|
|
11th |
13'-1" |
|
|
12th |
13'-1" |
|
|
14th |
13'-1" |
|
|
15th |
13'-1" |
|
|
16th |
13'-8" |
|
|
17th |
12'-11" |
|
|
18th |
14'-5" |
|
|
19th |
12'-4" |
|
|
20th |
14'-4" |
|
|
21st |
13'-0" |
|
|
22nd |
9'-11" |
|
|
23rd |
12'-1" |
|
|
24th |
11'-2" |
|
|
*Floor to underside of ceiling |
2. Windows:
Windows are operable for cleaning purposes only.
3. Floor Loading Capacity:
4. ADA Compliance:
An ADA report that has been prepared for all public access areas is
available for review by Tenants by request from the Owner.
|
5. Elevators: |
Low Rise Passenger Cars:
|
PE1 thru PE3
|
| |
a. Capacity (lbs): | 2,300 |
| |
b. Floors served: |
PE1-SB, B,L,3 thru 11 |
| |
|
PE2 & 3-L,3 thru 11
|
| |
a. Rated speed (fpm): | 700
|
| |
a. Clear door opening: | 3'-1"x7'-0"
|
| |
Cab materials: |
Stainless steel car fronts and transoms. |
| |
|
Wood wall panels and carpet flooring.
|
| |
High Rise Passenger Cars:
| PE 4 thru PE7 |
| |
a. Capacity (lbs): |
2,300
|
| |
b. Floors served: |
L,12 & 14 thru 23
|
| |
c. Rated speed (fpm): |
700
|
| |
d. Clear door opening: |
3'-1" x 7'-0"
|
| |
e. Cab materials: Stainless steel car fronts and transoms.
Wood wall panels and carpet flooring.
|
| |
Executive Elevator: | PE8
|
| |
a. Capacity (lbs): |
2,500
|
| |
b. Floors served: |
23,24
|
| |
c. Rated speed (fpm): |
75
|
| |
d. Clear door opening: |
3'-5"x7'-0"
|
| |
e. Cab materials: |
White plastic laminate door and wall
panels with stainless steel reveals.
|
| |
Service Elevator: |
SE1
|
| |
a. Capacity (lbs): |
2,500
|
| |
b. Floors served: |
SB,B,L, 2 thru 12 and
14 thru 23
|
| |
c. Rated speed (fpm): |
700
|
| |
d. Clear door opening:
|
3'-1"x7'-0"
|
| |
e. Cab materials: | Stainless steel walls, cab front, doors and
transom. Diamond plate flooring.
|
6. Storage Space:
The building has storage space
distributed between the sub-basement and basement
levels available for tenant use.
7. Electrical:
Electrical Service:
The building is served by three (3) 3,500 AMP,
120/208 volt, three phase, four wire services from
Con Edison. The electrical distribution is
comprised of a 120/208 volt conduit riser system
serving the base building loads and three 120/208
volt bus duct risers serving the tenant loads. A 600 AMP bus tap switch is provided
on each floor. Each tenant is directly metered by
Consolidated Edison Co. Power-Densities per floor are as follows:
| |
| Floor |
|
Watts/sf of usable area
exclusive of
floor AC unit
|
|
|
|
3 - 24 |
|
8 per floor
|
8. Emergency Generator
Provisions:
An Allis Calmer Company Emergency
Generator is located on the roof. The generator
has a capacity of 125 kw at 120/208 volt, three
phase, four wire, and serves stairs, emergency lighting
and base building, fire/life safety systems and
elevators.
9. Temperature Range:
Base building systems shall maintain
average indoor dry bulb temperatures not less than 68 degrees F,
whenever the outdoor dry-bulb temperature during
business day hours is lower than 65 degrees F and
not lower than 0 degrees F.
Base building systems shall maintain average indoor
dry-bulb temperatures no higher than 75 degrees F
whenever the outdoor dry-bulb temperature during
business day hours is higher than 65 degrees F and
not higher than 95 degrees F, and the outdoor wet-
bulb temperature does not exceed 75 degrees F.
The building system will furnish an average of not
less than .20 cubic feet per minute of outdoor fresh
air per usable square foot of tenant area.
The above performance specifications are based on an occupancy of
not more than one (1) person per
hundred (100) square feet of usable floor space and
an office electrical load of not more than 5 watts per
usable square foot.
Building System:
A/C systems for all tenant floors,
except 22nd floor,
consist of individual floor water, cooled, direct
expansion packaged VAV units. For floor 22,
cooling system will be either modular chillers with
ceiling mounted fan coil units or ceiling mounted
heat pumps with minimum fresh air ducted to each
space. The base building system is a variable air
volume system which permits the tenant to develop
multiple zones in the demised space.
Heating System:
The building is heated by Con Edison
steam. The base building heating equipment and circulation
pumps are located in the sub-basement of the
building. Heating is provided by perimeter fin tube
radiation on all floors with enclosures.
10. Roof Antenna:
Antenna space is available subject
to structural mounting limitations and adjacency
restrictions imposed by other antennas.
11. Sprinkler System:
Building provided with 3" sprinkler rig floor
control assembly at each tenant floor located in stair.
12. Plumbing System:
New ADA compliant men and women core toilets will be provided on each floor.
One 2" cold water valved outlet will be provided at
each core toilet for tenant as required and two
vent and sanitary stack locations with 4" SPO and 4"
VPO will be provided at each floor.
13. Communication
Capability:
Vertical and horizontal spaces have been allocated to receive fiber optic
communication facilities for tenant use. A vertical
communication riser closet is available at each floor.
14. Fire Alarm System:
A state of the art analog addressable fire
alarm system serves the building. The
fire command station is located in the lobby
concierge's desk and data gathering panels (DGP's)
are located on every third floor throughout
the building. The fire alarm system has
sufficient capacity for tenant additions on unoccupied floors. Each
floor is supplied with two speaker circuits, two strobe circuits, for ADA compliance (i.e. strobe lights), a
door release circuit at each DGP and addressable loop for the addition of smoke detectors, heat
detectors, etc.
15. Hours of Building
Operation:
8am-6pm Monday thru Friday, except holidays.